Best Crawl Space Dehumidifiers

Top pick: AlorAir Sentinel HDi65S for sealed crawl spaces up to 1,300 sq ft

Buy the AlorAir Sentinel HDi65S for a sealed or encapsulated crawl space of up to 1,300 square feet with no floor drain. AlorAir rates it at 55 pints per day at AHAM conditions (80°F, 60% RH) and 120 pints per day at saturation, and sizes it for 1,300 sq ft. It has a built-in condensate pump that AlorAir rates for a 19.6 ft drain height. The cabinet measures 19.2 x 12.2 x 13.3 inches, so it fits under joists where an upright unit won’t. AlorAir’s manual says to set it on a level surface of blocks or pavers, not directly on the vapor barrier.

Get AlorAir Sentinel HDi65S

It was chosen because it wins on four points at once. First, it has a built-in pump, which the Santa Fe and AprilAire units below don’t. Second, it shares the lowest documented operating temperature on this list with the HDi90 and HD55S, which AlorAir also rates down to 33.8°F: AlorAir’s manual gives a range of 33.8°F to 104°F and lists auto-defrost. Third, the warranty is 6 years limited, with full coverage for the first 2 years. Fourth, it costs much less than the 70-pint units: AlorAir’s own store lists it at $755.66 regular price, roughly half what retail listings ask for the Santa Fe Compact70 or the AprilAire E070.

Get Santa Fe Compact70 Get AprilAire E070

Who should skip it: anyone with more than 1,300 sq ft of crawl space, since that is past AlorAir’s own sizing for this unit, and anyone whose crawl space still has open foundation vents. AlorAir’s spec sheet gives a current draw of 4.1 A on 115 V and efficiency of 2.4 L/kWh. The humidity setpoint adjusts from 35% to 90% RH. AlorAir’s manual calls for a grounded 3-prong GFCI outlet on a 15 A circuit and says not to use an extension cord or plug adapter. It also says not to install the unit in a corrosive environment, to let any liquid vapor barrier dry completely first, and to wait at least 2 hours before switching on if the compressor did not stay upright. It needs 6 ft of clearance at the inlet and 36 in at the discharge.

These picks were not tested. They are based on each maker’s specification sheets and manuals and on retailer listings for each exact model. The rest of the list is ranked on the same criteria: AHAM capacity against the floor area, how the water leaves, cabinet height, lowest operating temperature, warranty and price.

AHAM pints, saturation pints and what fits under the joists

Crawl space units carry two capacity numbers. Compare them only like for like. The AHAM figure is measured at 80°F and 60% RH. AprilAire states the E070’s rated capacity at 80°F/60% RH inlet air at 0.0 in. external static pressure, and Santa Fe states the Compact70’s 70 pints at 80°F/60%. The saturation figure is measured in much wetter, hotter air. AlorAir’s HDi90 listing defines it as 90°F and 90% RH, which is why a 55-pint AHAM unit is sold as a 120 PPD dehumidifier. A 120-pint saturation unit is not a bigger machine than a 70-pint AHAM unit. It is a smaller one.

A real crawl space is cooler than 80°F, so every unit here removes less water there than its headline figure. The Santa Fe manual notes that the Compact70 is registered with the US Department of Energy as a portable dehumidifier with a capacity between 25 and 50 pints per day, rated at 43.75 pints per day at 65°F/60% RH. The DOE test procedure rates portable dehumidifiers at 65°F and 60% RH, so a DOE-listed capacity comes out below the 80°F number on the box.

Makers set floor-area ratings their own way, not to one shared standard. AlorAir sizes 55 AHAM pints for 1,300 sq ft and 90 AHAM pints for 2,600 sq ft. AprilAire sizes 70 pints for 2,200 sq ft, and Santa Fe sizes 70 pints for crawl spaces of 1,800 to 2,600 sq ft. When two makers’ sizing disagrees, go by the AHAM pints. The amount of water is real either way: 55 pints is about 6.9 gallons a day, and Santa Fe gives 8.75 gallons a day for the Compact70.

Check each cabinet height against the clearance under your joists. Here are the heights from the makers and listings:

Allow room above the cabinet for the drain hose and filter access.

Santa Fe Compact70: for crawl spaces over 1,300 sq ft

The Santa Fe Compact70 (model 4044110) is the one to buy when a sealed crawl space is too big for a 55-pint unit and headroom is tight. Santa Fe rates it at 70 pints a day (8.75 gallons) at 80°F/60% RH and sizes it for crawl spaces of 1,800 to 2,600 sq ft. Santa Fe’s warranty covers the whole unit for 5 years and its components for 6 years; that 6-year component term ties AlorAir’s 6-year limited warranty as the longest on this list. The Sylvane listing gives a weight of 55 lb and a height of 12 inches. Listings at Sylvane and OnlineSupply run roughly $1,400 to $1,800.

The installation manual lists what comes in the box: leveling feet, an 8 ft drain hose, a drain adapter and a MERV-13 filter measuring 0.75 x 9.00 x 11.38 in. There is no condensate pump. The unit drains by gravity to a floor drain or sump. Where neither sits lower than the unit, you need a separate condensate pump, which is one more part to buy, power and maintain under the floor.

Who should not buy it: anyone with a crawl space under 1,300 sq ft, where the HDi65S does the job for about half the price and includes the pump. Santa Fe’s product page gives an operating range of 49°F minimum to 95°F maximum. The manual says the unit works most effectively between 56°F and 95°F and that setting the humidity control to ‘dry’ is not recommended in rooms under 65°F. Replacement filters are the 0.75 x 9.00 x 11.38 in MERV-13 size, so stock that exact size rather than a generic furnace filter. Santa Fe says not to run the unit without a MERV-8, MERV-11 or MERV-13 filter (filter non-compliance voids the warranty) and to plug it into a Ground Fault Interrupter outlet. It must be installed indoors only, in a space protected from rain and flooding. If there is any possibility of flooding, suspend it from the floor joists with a hang kit, never by its cabinet; a flooded unit is not covered by warranty. It is not intended for use above 6,500 ft, or by persons with reduced physical, sensory or mental capabilities or lack of experience unless they are supervised or instructed.

AprilAire E070: for ducted, contractor-installed encapsulations

The AprilAire E070 suits a crawl space that a contractor is encapsulating and ducting. It also suits an install that should run on an AprilAire wall-mounted control. AprilAire rates it at 70 pints a day at 80°F/60% RH and 200 CFM, and sizes it for up to 2,200 sq ft. The cabinet is 12.5 x 12.5 x 25 inches. The manual gives a weight of 56 lb and an operating current of 5.4 A on 115 V. AprilAire’s manual requires a two-person lift and recommends installation, service and maintenance by a trained service technician. It says to place the unit so it plugs into a grounding-type outlet without an extension cord and to install it indoors only. Never operate it in standing water, do not use it in pool applications, and wait 24 hours before running it if it was not shipped or stored upright. It uses a flammable refrigerant, so keep it in a well-ventilated area away from continuously operating ignition sources. It is not intended for persons (including children) with reduced physical, sensory or mental capabilities or lack of experience unless they are supervised or instructed. The inlet and outlet have 8 in duct collars, so one unit can pull air from one bay and supply another. AprilAire limits total duct length to 100 ft and static pressure to 0.4 in. w.c., and says not to lay the intake duct on the crawl space floor. The drain is a ¾ in NPT fitting.

AprilAire’s warranty runs 5 years from the date of purchase and covers defects in materials and workmanship. AprilAire sells the E070 through its dealer network. Sylvane lists it bundled with a wall-mount control at $1,504.99. The E070 can also run a circulation mode that moves crawl space air without dehumidifying, to even out humidity and temperature between corners.

Who should not buy it: a DIY owner with no floor drain. The manual sends condensate to a floor drain or a condensate pump, and none is built in. The other case is a crawl space that drops below 50°F, the bottom of the dehumidification inlet range (50°F to 104°F) in AprilAire’s manual, against 33.8°F for the AlorAir units.

AlorAir Sentinel HDi90: most water removal, if the headroom allows

The AlorAir Sentinel HDi90 is for large or very wet crawl spaces with headroom to spare. AlorAir rates it at 90 pints a day at AHAM conditions and 198 pints at saturation (90°F/90% RH), and sizes it for up to 2,600 sq ft. AlorAir’s spec sheet gives 2.69 L/kWh, the highest efficiency figure on this list. Retailer listings give 210 CFM of airflow, a sound level under 58 dBA and the same 33.8°F to 104°F operating range as the HDi65S. Like the HDi65S, it has a built-in condensate pump and auto-defrost, and AlorAir also sells a duct-able version.

Get AlorAir Sentinel HDi90

The cost is size. Retailer listings give 23.2 x 15.2 x 17.7 inches and 70.5 lb. That is more than 4 in taller than the HDi65S and about 15 lb heavier than either 70-pint unit, and it all has to be carried through a crawl space hatch. AlorAir says to connect it to a grounded outlet without an extension cord or power adaptor. Set it on a level, steady surface, keep the area sealed, and keep 6 ft clear of obstructions.

Who should not buy it: anyone whose crawl space clearance doesn’t leave room for a 17.7 in cabinet plus hose routing, and anyone with a crawl space under about 1,800 sq ft. In a small crawl space, a 90-pint unit reaches its setpoint quickly and cycles on and off more often than a correctly sized one. Over 2,000 sq ft, the extra 20 AHAM pints over the 70-pint units are worth paying for, provided the clearance is there.

AlorAir Sentinel HD55S: the HDi65S without the pump

The AlorAir Sentinel HD55S shares the HDi65S figures: 55 pints a day at AHAM, 120 at saturation, 1,300 sq ft, and a 12.2 x 19.2 x 13.3 in cabinet. It drains by gravity only. AlorAir’s spec sheet for the Gold version gives a current draw of 4.1 A, and the HD55S appears on the ENERGY STAR certified dehumidifier list.

Get AlorAir Sentinel HD55S

Buy it only when a floor drain or sump pit sits lower than the unit’s drain outlet, so the hose falls all the way. AlorAir’s manual says the drain must flow down without loops, dips or valleys at a minimum slope of 1 in per 10 ft. The unit must be raised on blocks or pavers, not set directly on the vapor barrier or floor, unless it feeds a sump pump right beside it. It needs a grounded 3-prong GFCI outlet with no extension cord or plug adapter, and it will not run below 33.8°F or above 104°F. In that layout, the pump in the HDi65S does nothing except add a part that can fail. Who should not buy it: anyone who would have to add a separate condensate pump to make it work. At that point, the HDi65S with its pump built in is the simpler buy.

Drainage, power, upkeep, and what’s not worth the money

Plan drainage before choosing a unit. A gravity drain needs a hose that falls continuously from the outlet to a floor drain or sump. Any rise or sag holds water in the line. The Santa Fe Compact70 is the exception: Santa Fe requires a drain trap in the hose about 8 to 10 in from the unit, with the trap’s highest point at least 2 in below the drain port. AlorAir rates the HDi65S pump for a 19.6 ft drain height, enough to push water up to a rim joist and out; the HDi90 also has a built-in pump. If you add a separate condensate pump to the Santa Fe Compact70 or AprilAire E070, pick one rated above the vertical lift your hose run needs.

Power: all five units run on 115 V. AlorAir gives a current draw of 4.1 A for the HDi65S and HD55S and 5.56 A for the HDi90. AprilAire gives 5.4 A for the E070. Santa Fe gives 3.7 A for the Compact70 at 65°F/60% RH and 5.4 A at 104°F/36% RH. The National Electrical Code (NEC 210.8(A)) requires GFCI protection for receptacles in crawl spaces at or below grade, so check that the outlet the unit plugs into has it before the unit goes in.

Upkeep: the filter is the routine job. Santa Fe specifies a 0.75 x 9.00 x 11.38 in MERV-13 filter for the Compact70, and AlorAir fits the HDi65S with a filter that slides out the side, which matters when you are lying on a vapor barrier to reach it. A clogged filter cuts airflow, and with less airflow the unit removes less of its rated pints.

Not worth the money:

If the goal is drying the whole house through its ductwork rather than the space under the floor, a ducted unit is the right tool: see the best whole-house dehumidifiers.

FAQ

Do I need a crawl space dehumidifier with a built-in pump?

You need one when no floor drain or sump pit sits lower than the unit’s drain outlet. The AlorAir Sentinel HDi65S and HDi90 have built-in pumps; AlorAir rates the HDi65S pump for a 19.6 ft drain height. The Santa Fe Compact70, AprilAire E070 and AlorAir Sentinel HD55S drain by gravity, so without a drain they need a separate condensate pump.

What size crawl space dehumidifier do I need for 1,500 square feet?

That is past AlorAir’s 1,300 sq ft rating for its 55-pint units, so step up to a 70-pint AHAM unit. AprilAire sizes the E070 for up to 2,200 sq ft, and Santa Fe sizes the Compact70 for crawl spaces of 1,800 to 2,600 sq ft. Compare AHAM pints (80°F/60% RH), not saturation pints.

Will a crawl space dehumidifier work in a vented crawl space?

Not well. AprilAire describes the E070 as designed for sealed crawl spaces, and the floor-area ratings for all these units assume the space is closed off. With vents open, the unit spends its capacity on outdoor air coming in, so seal the vents and lay a vapor barrier before buying one.